01CT-5LPF1-4
Cable Temperature Sensor with mounting flange passive, NTC10k (10k2), Probe Length 8" [200 mm], Probe diameter 0.24" [6 mm], cable 9.8 ft [3 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5MH
Cable temperature sensor passive, NTC10k3 (Precon), Probe Length 2" [50 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5MH01
Cable temperature sensor passive, NTC10k3 (Precon), Probe Length 2" [50 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5ML
Cable temperature sensor passive, NTC10k3 (Precon), Probe Length 4" [100 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5ML01
Cable temperature sensor passive, NTC10k3 (Precon), Probe Length 4" [100 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5MLF1-4
Cable Temperature Sensor with mounting flange passive, NTC10k3 (Precon), Probe Length 4" [100 mm], Probe diameter 0.24" [6 mm], cable 9.8 ft [3 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5MP
Cable temperature sensor passive, NTC10k3 (Precon), Probe Length 8" [200 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5MP01
Cable temperature sensor passive, NTC10k3 (Precon), Probe Length 8" [200 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5MPF1-4
Cable Temperature Sensor with mounting flange passive, NTC10k3 (Precon), Probe Length 8" [200 mm], Probe diameter 0.24" [6 mm], cable 9.8 ft [3 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5QH
Cable temperature sensor passive, NTC20k, Probe Length 2" [50 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5QH01
Cable temperature sensor passive, NTC20k, Probe Length 2" [50 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5QL
Cable temperature sensor passive, NTC20k, Probe Length 4" [100 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5QL01
Cable temperature sensor passive, NTC20k, Probe Length 4" [100 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5QLF1-4
Cable Temperature Sensor with mounting flange passive, NTC20k, Probe Length 4" [100 mm], Probe diameter 0.24" [6 mm], cable 9.8 ft [3 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5QP
Cable temperature sensor passive, NTC20k, Probe Length 8" [200 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5QP01
Cable temperature sensor passive, NTC20k, Probe Length 8" [200 mm], Probe diameter 0.24" [6 mm], cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5QPF1-4
Cable Temperature Sensor with mounting flange passive, NTC20k, Probe Length 8" [200 mm], Probe diameter 0.24" [6 mm], cable 9.8 ft [3 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01DT-5AH
Duct/Immersion sensor Temperature passive, Pt100, Probe Length 2" [50 mm], Probe diameter 0.24" [6 mm]
01DT-5AL
Duct/Immersion sensor Temperature passive, Pt100, Probe Length 4" [100 mm], Probe diameter 0.24" [6 mm]
01DT-5AN
Duct/Immersion sensor Temperature passive, Pt100, Probe Length 6" [150 mm], Probe diameter 0.24" [6 mm]