EP200+AKRX-E
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 66, 14...250°F [-10...120°C]
EP200+AKRX-E N4
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 66, 14...250°F [-10...120°C]
EP200+AKRX-E N4HH
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 66, 14...250°F [-10...120°C]
EP200+AKRX-E N4HT
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 66, 14...250°F [-10...120°C]
EP200+ARX-E
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 66, 14...250°F [-10...120°C]
EP200+ARX-E N4
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 66, 14...250°F [-10...120°C]
EP200+ARX-E N4HH
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 66, 14...250°F [-10...120°C]
EP200+ARX-E N4HT
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 66, 14...250°F [-10...120°C]
EP200H+AKRX-E
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 100, 14...250°F [-10...120°C]
EP200H+AKRX-E N4
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 100, 14...250°F [-10...120°C]
EP200H+AKRX-E N4HH
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 100, 14...250°F [-10...120°C]
EP200H+AKRX-E N4HT
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 100, 14...250°F [-10...120°C]
EP200H+ARX-E
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 100, 14...250°F [-10...120°C]
EP200H+ARX-E N4
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 100, 14...250°F [-10...120°C]
EP200H+ARX-E N4HH
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 100, 14...250°F [-10...120°C]
EP200H+ARX-E N4HT
Configurable
Electr. PI-CCV EPIV, 2 vías, AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, DN 2"[50], Rosca interna, GPM 100, 14...250°F [-10...120°C]
EXT-LD14106BE1AX+PRBUP-3-T
Válvula de agua potable (BFV), DN 6" [150], 2 vías, ANSI Class Consistent with 125, Cv 1579
Actuador para válvula, Sin función de seguridad, AC 24...240 V / DC 24...125 V, On/Off (Encendido/Apagado), Punto flotante, 2x SPDT, Terminales
Actuador montado
EXT-LD14108BE1AX+PKRBUP-MFT-T
Válvula de agua potable (BFV), DN 8" [200], 2 vías, ANSI Class Consistent with 125, Cv 3136
Configurable
Actuador para válvula, Función de seguridad, AC 24...240 V / DC 24...125 V, 2...10 V, 2x SPDT, Terminales, BACnet MS/TP
Modbus RTU
MP-Bus, MFT/programable
Actuador montado
EXT-LD14108BE1AX+PKRXUP-MFT-T
Válvula de agua potable (BFV), DN 8" [200], 2 vías, ANSI Class Consistent with 125, Cv 3136
Configurable
Actuador para válvula, Función de seguridad, AC 24...240 V / DC 24...125 V, 2...10 V, 2x SPDT, Terminales, BACnet MS/TP
Modbus RTU
MP-Bus, MFT/programable
Actuador montado
EXT-LD14108BE1AX+PRBUP-3-T
Válvula de agua potable (BFV), DN 8" [200], 2 vías, ANSI Class Consistent with 125, Cv 3136
Actuador para válvula, Sin función de seguridad, AC 24...240 V / DC 24...125 V, On/Off (Encendido/Apagado), Punto flotante, 2x SPDT, Terminales
Actuador montado
Datos de diseño: Datos de diseño