EV500SU-495+GRX24-EV
Configurable
Electr. 2-way PI-CCV Belimo Energy Valve™, AC/DC 24 V, BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud, DN 5" [125], Flange, ANSI Class 125, V'nom 495 GPM, 14...250°F [-10...120°C]
EV500SU-495-250+GKRX24-EV
Configurable
Electr. 2-way PI-CCV Belimo Energy Valve™ fail-safe, AC/DC 24 V, BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud, DN 5" [125], Flange, ANSI Class 250, V'nom 495 GPM, 14...250°F [-10...120°C]
EV500SU-495-250+GRX24-EV
Configurable
Electr. 2-way PI-CCV Belimo Energy Valve™, AC/DC 24 V, BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud, DN 5" [125], Flange, ANSI Class 250, V'nom 495 GPM, 14...250°F [-10...120°C]
EV600SU-713+GKRX24-EV
Configurable
Electr. 2-way PI-CCV Belimo Energy Valve™ fail-safe, AC/DC 24 V, BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud, DN 6" [150], Flange, ANSI Class 125, V'nom 713 GPM, 14...250°F [-10...120°C]
EV600SU-713+GRX24-EV
Configurable
Electr. 2-way PI-CCV Belimo Energy Valve™, AC/DC 24 V, BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud, DN 6" [150], Flange, ANSI Class 125, V'nom 713 GPM, 14...250°F [-10...120°C]
EV600SU-713-250+GKRX24-EV
Configurable
Electr. 2-way PI-CCV Belimo Energy Valve™ fail-safe, AC/DC 24 V, BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud, DN 6" [150], Flange, ANSI Class 250, V'nom 713 GPM, 14...250°F [-10...120°C]
EV600SU-713-250+GRX24-EV
Configurable
Electr. 2-way PI-CCV Belimo Energy Valve™, AC/DC 24 V, BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud, DN 6" [150], Flange, ANSI Class 250, V'nom 713 GPM, 14...250°F [-10...120°C]
GKB24-IP
Damper Actuator, 360 in-lb [40 Nm], Electronic fail-safe, AC/DC 24 V, Modulating, Communicative, Hybrid, Cloud, Cloud, BACnet/IP, Modbus TCP
GM24A-MOD
Rotary Actuator, 360 in-lb [40 Nm], AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, 2...10 V, 150 s (75...290 s), IP54
GMB24-IP
Damper Actuator, 360 in-lb [40 Nm], Non fail-safe, AC/DC 24 V, Modulating, Communicative, Hybrid, Cloud, Cloud, BACnet/IP, Modbus TCP
LF24-VST
Rotary actuator fail-safe for VRU, 35 in-lb [4 Nm], AC/DC 24 V, 120 s, IP54
LHV-D3-MP-100
Volumetric flow controller VAV-Compact linear, 150 N [35 lbf], AC/DC 24 V, MP-Bus, 2...10 V, 150 s, Stroke 4" [100 mm]
LM24A-MOD
Rotary Actuator, 45 in-lb [5 Nm], AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, 2...10 V, 150 s (35...150 s), IP54
LMB24-IP
Damper Actuator, 45 in-lb [5 Nm], Non fail-safe, AC/DC 24 V, Modulating, Communicative, Hybrid, Cloud, Cloud, BACnet/IP, Modbus TCP
LR24A-MOD
Rotary Actuator, 45 in-lb [5 Nm], AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, 2...10 V, 90 s (35...150 s), IP54
LRB24-IP
Valve Actuator, Non fail-safe, AC/DC 24 V, Modulating, Communicative, Hybrid, Cloud, Cloud
BACnet/IP
Modbus TCP
NF24A-MOD
Rotary actuator fail-safe, 90 in-lb [10 Nm], AC/DC 24 V, BACnet MS/TP, Modbus RTU, MP-Bus, 2...10 V, 150 s (40...150 s), IP54
NF24A-VST
Rotary actuator fail-safe for VRU, 90 in-lb [10 Nm], AC/DC 24 V, 120 s, IP54
Design Data : Design Data