22PF-5UJ
Flow sensor, AC/DC 24 V, DN 65, FS 10.6 l/s, ANSI Class 250, NEMA 2
22PF-5UJ-1
Flow sensor, AC/DC 24 V, DN 65, FS 10.6 l/s, ANSI Class 125, NEMA 2
22PF-5UK
Flow sensor, AC/DC 24 V, DN 80, FS 16.7 l/s, ANSI Class 250, NEMA 2
22PF-5UK-1
Flow sensor, AC/DC 24 V, DN 80, FS 16.7 l/s, ANSI Class 125, NEMA 2
22PF-5UL
Flow sensor, AC/DC 24 V, DN 100, FS 25.0 l/s, ANSI Class 250, NEMA 2
22PF-5UL-1
Flow sensor, AC/DC 24 V, DN 100, FS 25.0 l/s, ANSI Class 125, NEMA 2
22PF-5UM
Flow sensor, AC/DC 24 V, DN 125, FS 41.7 l/s, ANSI Class 250, NEMA 2
22PF-5UM-1
Flow sensor, AC/DC 24 V, DN 125, FS 41.7 l/s, ANSI Class 125, NEMA 2
22PF-5UN
Flow sensor, AC/DC 24 V, DN 150, FS 62.5 l/s, ANSI Class 250, NEMA 2
22PF-5UN-1
Flow sensor, AC/DC 24 V, DN 150, FS 62.5 l/s, ANSI Class 125, NEMA 2
01CT-5AH
Cable temperature sensor passive, Pt100, Probe Length 2" [50 mm], Probe diameter 0.24" [6 mm], Cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5BH
Cable temperature sensor passive, Pt1000, Probe Length 2" [50 mm], Probe diameter 0.24" [6 mm], Cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5BL
Cable temperature sensor passive, Pt1000, Probe Length 4" [100 mm], Probe diameter 0.24" [6 mm], Cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5BP
Cable temperature sensor passive, Pt1000, Probe Length 8" [200 mm], Probe diameter 0.24" [6 mm], Cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5EH
Cable temperature sensor passive, Ni1000 (JCI), Probe Length 2" [50 mm], Probe diameter 0.24" [6 mm], Cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5LH
Cable temperature sensor passive, NTC10k (10k2), Probe Length 2" [50 mm], Probe diameter 0.24" [6 mm], Cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5LH01
Cable temperature sensor passive, NTC10k (10k2), Probe Length 2" [50 mm], Probe diameter 0.24" [6 mm], Cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5LL
Cable temperature sensor passive, NTC10k (10k2), Probe Length 4" [100 mm], Probe diameter 0.24" [6 mm], Cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
01CT-5LL01
Cable temperature sensor passive, NTC10k (10k2), Probe Length 4" [100 mm], Probe diameter 0.24" [6 mm], Cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG bare copper, black jacket, -13...167° [-25...75°C], 300 V
01CT-5LP
Cable temperature sensor passive, NTC10k (10k2), Probe Length 8" [200 mm], Probe diameter 0.24" [6 mm], Cable 6.5 ft [2 m], 2-wire, 1 pair shielded plenum cable, 22AWG tinned copper, green jacket, -40...300°F [-40...150°C], 300 V
Design Data : Design Data